Flexcon dermaflex
dfm 100 clear H-566

documents

Technical Data sheet

Features and Benefits
    • Double-face (2-sided) tape suitable for mounting & bonding applications, such as medical device attachment to the body
    • H-566 high-tack acrylic adhesive with high strength for extended wear, such as attachment of long-term wearable devices
    • Backed with an 80-lb. moisture stable polycoated layflat release liner suitable for roll form, roll to sheet, and sheet form converting

technical data

Values
Thickness (Mils[microns])
Adhesive
1.9-2.1 (48-53) +/- 0.1 (3)
Film
1.0 (25) +/- 10%
Adhesive
1.9-2.1 (48-53) +/- 0.1 (3)
Liner
5.6 (142) +/- 10%

ADHESION properties

Ultimate Peel From
Average Oz/In
(N/m)
Acrylic
137
(1507)
Glass
51
(561)
Polypropylene
51
(561)
Stainless Steel
116
(1276)

Electrical properties

Property
Value
Test Method
Expected Shear
Room Temp (hours): 5
ASTM D 3654 Method A, a. 1 hr. dwell, b. 1 sq. in. surface, c. 4 lb. load
Tack (gm/sq cm)
900
ASTM D 2979
Storage Stability
Two years stored at 70°F (21°C) and 50% relative humidity

Product ID # FLX068984

All of the descriptive information, the typical performance data, and recommendations for the use of FLEXcon products shall be used only as a guide and do not reflect the specification or specification range for any particular property of the product. Furnishing such information is merely an attempt to assist you after you have indicated your contemplated use and shall in no event constitute a warranty of any kind by FLEXcon. All purchasers of FLEXcon products shall be responsible for independently determining the suitability of the material for the purpose for which it is purchased. No distributor, salesman, or representative of FLEXcon is authorized to give any warranty, guarantee, or make any representation in addition or contrary to the above.