Avery Dennison
MED 5734

Double-Coated Nonwoven with Gentle Adhesive

MED 5734 is a double-coated, white nylon nonwoven with a gentle acrylic adhesive designed to adhere to the skin, with the acrylic side adhesive with good initial tack and adhesion that is suitable for a wide variety of materials. The softness, conformability, and the repositionability of the adhesive offers a high degree of user comfort.


Typical Application

MED 5734 was created for skin-contact applications that require flexibility and a gentler “soft” release at the onset of use without sacrificing static sheer. This unique performance mechanism—the ability to remove, reposition and replace—remains active for 48 hours before reverting to traditional acrylic adhesion.

documents

Technical Data sheet

Features and Benefits
    • Delivers “soft” release from skin during first 48 hours of contact
    • Allows atraumatic repositioning or temporary removal
    • Static shear and liner release of normal acrylic adhesive
    • Acrylic adhesive can be applied to a wide variety of materials
    • Sterilization compatibility with Ethylene Oxide (EtO) and Gamma Irradiation
Physical Properties (Not intended as a specification.)
Test Method**
Typical Values*
Acrylic PSA (Paper Liner)
Peel Adhesion on Stainless Steel (SS)
TDS-04
2.5 lbf/in 2.2 N/25 mm
90 Degree Liner Release
TDS-06
120 lbf/in
Gentle Acrylic PSA (PET Liner)
Peel Adhesion on Stainless Steel (SS)
TDS-06
0.2 lbf/in 2.2 N/25mm
90 Degree Liner Release
TDS-16
100 gf/2 in 2.2 oz/in
Product Construction
Typical Values*
Description
Patient Liner Thickness
2 mils 51 µm
Clear PET film
Patient Gentle Adhesive Thickness
1 mils 25 µm
Gentle acrylic adhesive designed for medical applications
Nonwoven Carrier
9 mils 229 µm
White nylon nonwoven
Acrylic Adhesive thickness
1 mils 25 µm
Acrylic adhesive with good initial tack and adhesion
Acrylic Liner thickness
3 mils 76 µm
White single-coated kraft paper liner

*Refer to product specifications for material acceptance limits.
**Test method information available upon request.

Performance Statement:

Wear time based on internal studies should be used only as a guide; results may vary and may be influenced by environmental, use, device design and user attributes. It is recommended that customers conduct their own studies using their specific device design to determine accurate wear times.

STORAGE AND SHELF LIFE

Two years when stored at 23°C (73°F), 50% relative humidity, out of direct sunlight, in original packaging.